Black waterproofing membrane covering a foundation wall below red brick, open trench in front

Why sump pumps quit in a Michigan winter and what to check

Frozen discharge lines, January thaws and ice-storm outages are why Michigan sump pumps fail in winter. Freeze guards, backups and a 20-minute test.

What will it cost?See approximate prices for your basement in about 30 seconds. Free, no phone number needed.

Updated

It’s usually a Sunday in late January. It was nine degrees on Thursday, now it’s 45 and raining on top of two feet of old snow, and somebody is standing in an inch of water next to a sump pump that is running and running and not moving a drop. Outside, the discharge pipe is a solid tube of ice.

We get some version of that call every winter. The pump usually isn’t broken. It’s doing exactly what it was built to do, into a pipe that has nowhere to go.

Spring is busy, but winter is when pumps fail

A pump runs the most in March and April. It fails the most in January and February, because everything around it is working against it.

When the ground is frozen at the surface, snowmelt can’t soak in where it lands. Frost here goes deep enough that Michigan’s residential code puts footings 42 inches down. So meltwater runs along the top of the frozen layer until it finds the one soft spot in the yard, which is the loose backfill around your foundation. It drops straight down that backfill to the footing, into the drain tile, and into your pit.

That’s why a quick thaw on frozen clay can fill a sump faster than a summer thunderstorm. And it happens at exactly the moment the discharge line is most likely to be frozen shut.

How a discharge line freezes solid

In winter the pump cycles a few times a day instead of running steady. Between cycles, whatever water is left in the outdoor part of the pipe just sits there. If the line runs flat, dips, or ends in a long black flex hose lying across the lawn, that leftover water freezes. Each cycle adds a little more ice until the pipe closes up.

These are the setups we see freeze most often.

  • Corrugated flex hose. The ridges hold water. Fine in July, a bad bet from December to March.
  • Pipe buried a few inches deep and run out to a pop-up emitter in the yard. It freezes from the far end back, and you can’t see it happening.
  • A line with a low belly where it crosses a sidewalk or runs uphill to get over a flower bed.
  • Any line that ends where the snow gets piled, like the side of the driveway the plow blade throws everything onto.

The fix is boring. Rigid PVC, pitched so it drains empty after every cycle, ending somewhere snow doesn’t pile up. If it goes underground it either goes below frost or it’s pitched steep enough that it never holds water.

We install and replace these lines. See sump pump discharge lines.

What a freeze guard actually does

A freeze guard is a fitting that goes on the discharge line right after it comes out of the house wall. It has an opening in it. When the pipe downstream is clear, water flows past that opening and goes where it’s supposed to. When the pipe ices shut, the water backs up and spills out the opening instead, onto the ground a foot or two from the house.

That isn’t great. Water next to the foundation is the thing you bought a pump to get rid of. But it beats the alternative, where the pump runs against a blocked line, overheats, and the pit overflows into the basement. Think of it as a relief valve you hope never runs.

An air gap does a similar job where a sump line drops into a buried drain. The pump empties into an open fitting instead of a sealed pipe, so if the underground part freezes or clogs, the water spills out above ground instead of backing up into the house. While you’re looking at that connection, know that a lot of Michigan towns don’t allow sump water into the sanitary sewer at all. If your line goes into a floor drain or a laundry tub, that’s worth fixing for more than one reason.

Ice storms and a melting yard

February 2023 is the one people around here still bring up. Ice came down on the 22nd, wires came down with it, and DTE said more than 630,000 customers lost power. Some went four or five days, and a second round of ice a few days later knocked some of them out again. Meanwhile it warmed up, and everything that had been ice started heading into the ground.

No power, a thaw and a full pit. That’s the combination that floods finished basements, and it’s why we push backup pumps harder than anything else we install.

Battery backup

A second pump in the same pit, on its own float, running off a deep-cycle battery. It takes over when the main pump quits or the power goes out. A good one will carry you through an ordinary outage. The weak spot is the battery. They wear out quietly, and a multi-day outage during a heavy melt can run one flat. Replace the battery on a schedule instead of waiting to find out it’s dead.

Water-powered backup

This one runs on city water pressure. Pressurized water goes through a jet that creates suction and pulls water out of the pit, and the makers figure roughly two gallons pumped out for every gallon of city water used. There’s no battery to die. It keeps going as long as the water main has pressure, and it has to have a backflow preventer so pit water can never get into your drinking water.

It does not work on a private well, because the well pump needs electricity too. For most of Macomb and south Oakland, on municipal water, it’s the backup we’d pick. Out in the townships on a well, it’s a battery.

Either way, the backup’s discharge has to follow the same freeze rules. A backup pumping into a frozen pipe isn’t a backup.

We install both kinds. See battery backup sump pump installation and water-powered backup sump pumps.

That bang when the pump shuts off

Most people only notice the check valve when it makes noise. It’s the fitting on the discharge pipe a little above the pump, and its job is to stop the column of water in the pipe from falling back into the pit when the pump stops. A loud thunk at shutoff is the flapper slamming closed. It’s annoying and usually harmless, and a quiet-closing check valve takes care of it.

The one to worry about is the valve that doesn’t close. You’ll hear water gurgle back into the pit after the pump stops, and the pump will kick on again sooner than it should. In winter that means more cycles, more leftover water sitting in the outdoor line to freeze, and more wear on a motor that is already working hard. A check valve is a cheap part. Swap it when it starts acting up.

We replace failed check valves and clear frozen or clogged lines on a sump pump repair visit.

A Saturday morning test

About twenty minutes. Do it once in November before the ground freezes, and again in late January before the first big thaw.

  • Take the lid off and look in the pit. Gravel, silt or a sock the dog dropped in there can hang up the float.
  • Pour water in from a five-gallon bucket until the main pump starts. It should kick on well before the water gets near the rim, and empty the pit without straining.
  • Listen at shutoff. A thunk is fine. Water rushing back into the pit is not.
  • Unplug the main pump and fill the pit again. The backup should pick it up. If it has an alarm and a test button, press the button.
  • If you have a battery backup, check the date on the battery.
  • Go outside to where the line leaves the house and follow it to the end. Kick the snow away from the outlet and look for ice at the freeze guard opening.
  • Plug the main pump back in. People forget this one.

If your pump runs almost nonstop, struggles on the bucket test, or sits in an open pit with no backup, have that conversation in the fall rather than in the middle of a January thaw. Our sump pump page has what we install, including both kinds of backup. If it’s already too late and the water is on the floor, we pick up the phone at two in the morning too.

Frequently asked questions

Why does my sump pump run but not pump any water in winter?

The discharge line outside is usually frozen. The pump is doing its job, but the pipe is a solid tube of ice and the water has nowhere to go. The pump usually is not broken.

How do I keep a sump pump discharge line from freezing?

Use rigid PVC pitched so it drains empty after every cycle, and end it somewhere snow does not pile up. If the line goes underground, it either goes below frost or is pitched steep enough that it never holds water. Corrugated flex hose holds water in its ridges and is a bad bet from December to March.

What does a freeze guard do on a sump pump line?

It is a fitting with an opening, placed on the discharge line right after it leaves the house wall. If the pipe downstream ices shut, the water spills out of the opening onto the ground instead of backing up, so the pump does not run against a blocked line and overflow the pit.

Which backup pump is better in a power outage, battery or water-powered?

A battery backup runs off a deep-cycle battery, and a multi-day outage during a heavy melt can run it flat. A water-powered backup runs on city water pressure and has no battery to die, but it does not work on a private well. On municipal water we would pick the water-powered one, and on a well it is a battery.

Why does my sump pump bang when it shuts off?

That is the check valve flapper slamming closed. It is usually harmless, and a quiet-closing check valve takes care of it. Water gurgling back into the pit after the pump stops means the valve is not closing, and it should be swapped.

When should I test my sump pump for winter?

Once in November before the ground freezes, and again in late January before the first big thaw. The test takes about twenty minutes.

Ready to Protect Your Basement?

Don’t wait for the next big storm. Contact us today for a free flood-risk evaluation and estimate.

Have an invoice from us? Pay it online in under a minute.Card, Apple Pay, Google Pay or Cash App. Deposits, invoices and prepayments.

Pay Your Invoice Now